| Product Design and Fabrication | GB/T 8478 | Technical requirements for aluminum alloy building doors and windows used in the Chinese market. | Profile dimensions, assembly quality, hardware installation, sealing, glazing, operation, and finished-product performance should be assessed against the applicable product and project requirements. | Product specification, approved drawings, material list, quality-control plan, and third-party or factory test reports. |
| European Market Performance | EN 14351-1 | Performance characteristics for windows and external pedestrian doorsets, including air permeability, watertightness, wind resistance, acoustic performance, and thermal properties where applicable. | Performance is declared for the specific door configuration, including frame, glass, hardware, dimensions, and opening type. Results should not be transferred to a different configuration without technical justification. | Performance declaration, product test report, classification report, and factory production-control documentation. |
| Factory Quality Management | ISO 9001 | Quality-management processes covering purchasing, production, inspection, corrective action, document control, and customer feedback. | ISO 9001 is a management-system certification; it does not by itself certify the performance of a specific aluminum door. | Valid certificate showing the certified legal entity, manufacturing scope, site address, certification body, and validity period. |
| Environmental Management | ISO 14001 | Environmental-management controls for manufacturing activities, resource use, waste handling, and environmental compliance. | This certification evaluates the management system rather than the product’s thermal, structural, or weather-performance ratings. | Current certificate, certified site information, environmental procedures, and relevant compliance records. |
| Aluminum Alloy Profiles | EN 755 / EN 12020 or applicable GB/T material standard | Profile dimensional tolerances, mechanical properties, surface condition, and extrusion quality, depending on the selected alloy and profile series. | Alloy and temper, wall thickness, dimensions, straightness, torsion, surface quality, tensile strength, yield strength, and elongation should match the approved specification. | Mill certificates, chemical-composition records, mechanical test results, incoming-inspection records, and profile dimensional reports. |
| Powder Coating | AAMA 2603, AAMA 2604, or AAMA 2605 | Performance levels for organic coatings on aluminum, including appearance, adhesion, weathering, and corrosion resistance. | AAMA 2605 provides a higher exterior-durability level than AAMA 2604 and AAMA 2603. The selected class should match exposure conditions, color, building location, and warranty requirements. | Coating-system specification, pretreatment details, coating thickness records, adhesion results, color data, and accelerated-weathering or corrosion-test reports where required. |
| Anodized Finish | AAMA 611 or ISO 7599 | Anodic finishes for architectural aluminum, including coating thickness, appearance, sealing, and durability characteristics. | Specify anodic coating class or thickness, color tolerance, gloss or appearance requirements, sealing quality, and surface uniformity for exposed elevations. | Anodizing process specification, coating-thickness readings, sealing test records, approved color sample, and batch inspection report. |
| Air Permeability | ASTM E283 or EN 1026 | Air leakage through joints and seals under a controlled pressure difference. | Results are reported as air-flow rate at a stated pressure difference. A lower leakage rate indicates better air tightness; the required limit depends on the project specification and classification system. | Laboratory report identifying the tested size, configuration, pressure difference, leakage result, weather seals, and hardware. |
| Water Penetration | ASTM E331 or EN 1027 | Resistance to water entry through the closed door assembly under static or dynamic pressure conditions. | Test pressure, duration, spray rate, specimen size, drainage design, and any observed leakage should be recorded. The specified pressure must reflect the project exposure and performance class. | Water-penetration test report, installation details, drainage-path drawings, and corrective-action records for failed samples. |
| Structural Wind Resistance | ASTM E330/E330M or EN 12211 | Deflection, permanent deformation, and structural integrity under positive and negative pressure loads. | Reports should state design pressure, test pressure, specimen dimensions, maximum deflection, permanent deformation, glass condition, and hardware performance after testing. | Structural calculation, signed test report, profile inertia data, anchor layout, and confirmation that the tested configuration matches the supplied design. |
| Thermal Performance | ISO 10077-1/2 or EN 12412-2 | Thermal transmittance of frames, doorsets, glazing, and junctions, including the effect of thermal breaks. | U-values are configuration-dependent. The declared value should identify frame material, thermal-break geometry, glass build-up, spacer, dimensions, and calculation or test method. | Thermal calculation, hot-box test report where applicable, glazing specification, thermal-break data, and condensation-risk assessment. |
| Acoustic Performance | ISO 10140-2 and ISO 717-1 | Laboratory airborne sound insulation of the complete door or glazed doorset. | Sound-reduction values depend on the complete assembly, including glass, seals, frame, threshold, hardware, and installation. The tested configuration should match the proposed product. | Acoustic test report, glass make-up, seal details, threshold design, and installation guidance. |
| Glass Safety | EN 12150, EN 14449, or applicable local glazing standard | Safety and conformity requirements for toughened or laminated safety glass used in exterior doors. | Glass type, thickness, heat treatment, interlayer, impact classification where required, edge quality, and marking should be verified before installation. | Glass certificate, safety-glass marking, batch traceability, thickness records, and compliance declaration from the glass processor. |
| Hardware and Cycle Testing | EN 1191, EN 12400, or project-specific hardware standard | Operational durability of hinges, locks, rollers, closers, handles, and other moving components. | Cycle count, load condition, hardware adjustment, closing force, locking function, wear, corrosion condition, and post-test operation should be documented. | Hardware technical data, cycle-test report, corrosion-test information, maintenance instructions, and replacement-part availability statement. |
| Factory Production Control | Documented inspection and traceability procedure | Controls from raw-material receipt through cutting, machining, assembly, glazing, finishing, final inspection, packing, and shipment. | Typical checks include profile dimensions, corner joints, fasteners, seal continuity, glass setting blocks, hardware operation, coating appearance, drainage, labels, and packaging condition. | Inspection and test plan, in-process checklists, nonconformance records, calibration certificates, batch numbers, and final inspection report. |
| Installation and Site Verification | Project specification and applicable local installation code | Anchorage, perimeter sealing, shimming, drainage, tolerance control, interface with masonry or Curtain Wall Systems, and protection after installation. | Verify opening dimensions, plumb and level, anchor spacing, sealant compatibility, weep paths, glass support, hardware adjustment, and final operation. Field water or air testing may be required for critical elevations. | Approved method statement, shop drawings, installation checklist, sealant data sheet, site inspection records, and field-test report. |